5-20
Series3800/S120R-2 (6025B-3/6025B-3R) User's Manual
JLAN Enable/Disable
Change the setting of jumper JPL1 or
JPL2 to enable or disable the onboard
LAN ports JLAN1 and JLAN2, respec-
tively. See the table on the right for
jumper settings. The default setting
is enabled
JLAN Enable/Disable
Jumper Settings (JPL1, JPL2)
Jumper Setting De nition
Pins 1-2 Enabled
Pins 2-3 Disabled
3rd Power Supply Fail Detect
Enable/Disable
The system can notify you in the event
of a power supply failure. This feature
assumes that three power supply units
are installed in the chassis with one
acting as a backup. If you only have
one or two power supply units installed,
you should disable this (the default set-
ting) with J3P to prevent false alarms.
See the table on right for jumper set-
tings.
Note: JP10 should be disabled on the
6025B-3, which has only a single pow-
er supply.
3rd Power Supply Fail
Detect Enable/Disable
Jumper Settings (J3P)
Jumper Setting De nition
Open Disabled
Closed Enabled
Compact Flash Master/
Slave
The JCF1 jumper allows you to assign
either master or slave status to the
compact ash card. See the table on
the right for jumper settings.
Compact Flash
Master/Slave
Jumper Settings (JCF1)
Jumper Setting De nition
Closed Master
Open Slave