Monitoring the failures of the tape device is desired
NEC ESMPRO Agent does not monitor the failures of the tape device. If want to conduct monitoring, use
backup software or tape monitoring application. Using the event monitoring function of NEC ESMPRO
Agent allows you to monitor the event log of backup software or applications.
Changing setting of storage monitoring
The following setting will not take effect until one (old) monitoring interval cycle of each monitoring service
passes after changes are made to setting.
sampling interval (Polling Frequency tab of storage setting) reset (Reset tab of storage setting and Reset
on hard disk drive General view in [Information of server state/constitution] of NEC ESMPRO Manager)
hard disk drive pre-failure prediction mode (HD Pre-failure tab of storage setting) thresholds of free block
monitoring (Free Space tab of storage setting and threshold on File System General view in [Information of
server state/constitution] of NEC ESMPRO Manager).
Changing mode of Hard disk drive pre-failure prediction
Turning on/off the mode of hard disk drive pre-failure prediction, all hard disk drives work in the same
mode in either case. Cannot set the mode of each hard disk drive individually.
Storage Devices other than SCSI/IDE Device
NEC ESMPRO Agent does not monitor storage devices other than SCSI/IDE devices (e.g., USB device).
Display of [Information of server state/constitution] of NEC ESMPRO
Manager when Hard disk drive is connected
In the case of using LSI RAID system, even if you connect hard disk drive to RAID Controller, the
connected hard disk drive cannot be displayed of [Information of server state/constitution] of NEC
ESMPRO Manager.
In such a case, recognize the hard disk drive by RAID system configuration.
Network drive is not displayed of [Information of server state/constitution]
of NEC ESMPRO Manager
The drive connected to network is not displayed under the file system tree in [Information of server
state/constitution] of NEC ESMPRO Manager.