NEC Express5800/340Hb-R Guía de usuario

Busca en linea o descarga Guía de usuario para Software de gestión de sistemas NEC Express5800/340Hb-R. NEC Express5800/340Hb-R User's Guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 312
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - User's Guide

N8800-047F/073F NEC Express5800/340Hb-R User's Guide 1st Edition 3-2005 856-125126-901-A

Pagina 2

iv CONTENTS PREFACE... i ABOU

Pagina 3 - SAFETY INDICATIONS

3-24 Windows Setup and Operation 4. When [Op State: State] becomes [Duplex], the resynchronization is completed. [Resynchronization without spe

Pagina 4 - Mandatory actions

Windows Setup and Operation 3-25 Replacing Failed Hard Disk Drives Follow the procedure below to locate and replace the failed hard disk. The fail

Pagina 5

3-26 Windows Setup and Operation Procedures to Replace Failed Disks Models that do not support the RDR function When a failure occurs on a disk mi

Pagina 6 - To prevent voltage sag:

Windows Setup and Operation 3-27 4. Right-click a volume that has “!”, and remove mirror. 5. After checking to see the “Missing” disk

Pagina 7 - PREFACE

3-28 Windows Setup and Operation 7. Similarly, delete the other [Missing] disk. 8. Insert new disks. They will appear

Pagina 8 - ABOUT THIS USER'S GUIDE

Windows Setup and Operation 3-29 9. Select and right-click a disk, and then select [Convert to Dynamic Disk]. IMPORTANT: If [Foreign] appear

Pagina 9 - Accessories

3-30 Windows Setup and Operation 10. Open the disk’s properties to check the target IDs. In the following figures, disks are configured as: Disk 1

Pagina 10 - CONTENTS

Windows Setup and Operation 3-31 11. Make a mirror setting of Disks 1 and 4. Right-click volume (E) on the Disk 4 and select [Add Mirror].

Pagina 11

3-32 Windows Setup and Operation Models supporting the RDR function This section explains the procedure for replacing a disk which is duplexed by t

Pagina 12

Windows Setup and Operation 3-33 CHANGE DRIVE LETTER To add, change or delete drive letters, follow the steps below. Before making any changes, t

Pagina 13

v Power-On Self Test (POST) ... 2-32 Floppy Disk Drive...

Pagina 14

3-34 Windows Setup and Operation DUAL LAN CONFIGURATION The NEC Express5800/ft series builds a dual LAN configuration by using "Stratus emb-82

Pagina 15 - Chapter 1

Windows Setup and Operation 3-35 [Team #1: Adaptive Fault Tolerance Mode] is added to Network Component Tree. 3. Select [Stratus emb-82559 10

Pagina 16 - WARNING LABELS

3-36 Windows Setup and Operation 6. Click [OK]. The [Intel(R)PROSet II] dialog box closes after a while, and the settings become effective. IMPOR

Pagina 17

Windows Setup and Operation 3-37 Removing dual LAN TIPS: To set dual LAN configuration, log on as "Administrator" or a member of the grou

Pagina 18 - CPU Module

3-38 Windows Setup and Operation <For on-board > - Stratus emb-82559 10/100 Enet Adapter - Stratus emb-82544GC Copper Gigabit Adapter <

Pagina 19 - PCI Module

Windows Setup and Operation 3-39 4. Click the [OK] button on the [Intel PROSet II] dialog box, close it, and make a setup effective. The dual LAN

Pagina 20 - 1-6 Precautions for Use

3-40 Windows Setup and Operation CHECK THE DUPLICATING OPERATION OF MODULES This section describes how to check if the system runs properly after s

Pagina 21 - Expansion PCI Module

Windows Setup and Operation 3-41 3. Stop the operation of a PCI module using the ft server utility. Select [Start] - [All Programs] - [NEC ESMPR

Pagina 22 - 1-8 Precautions for Use

3-42 Windows Setup and Operation IMPORTANT: If BrightStor ARCserve 2000 or Backup Exec is installed, the tape will not be recognized due to the fai

Pagina 23 - PRECAUTIONS FOR SAFETY

Windows Setup and Operation 3-43 Evaluate Start and Stop of CPU Modules This section describes how to confirm the continuous system operation after

Pagina 24

vi Chapter 6 Maintenance... 6-1 DAILY MAINTENANCE...

Pagina 25

3-44 Windows Setup and Operation When you stop the operation of a CPU module, the indications of the status LEDs change as follows. Below denotes t

Pagina 26

Windows Setup and Operation 3-45 Evaluate Start and Stop of Expansion PCI Modules This section describes how to confirm the continuous system opera

Pagina 27

3-46 Windows Setup and Operation change as follows. Below denotes that the only one expansion PCI module is operating. [Indications of status LE

Pagina 28 - During Operation

Windows Setup and Operation 3-47 NEC Express5800/ft series SERVICE PROGRAM CONFIGURATION NEC Express5800/ft series achieves the duplex system usi

Pagina 29 - Rack-mount Model

3-48 Windows Setup and Operation (This page is intentionally left blank.)

Pagina 30

Chapter 4 System Configuration This chapter describes Basic Input Output System (BIOS) configuration. When you install the server for the first time

Pagina 31 - For Proper Operation

4-2 System Configuration SYSTEM BIOS ~ SETUP ~ The SETUP utility is provided to make basic hardware configuration for the server. This utility is pre

Pagina 32 - 1-18 Precautions for Use

System Configuration 4-3 Starting SETUP Utility Powering on the server starts POST (Power On Self-Test) and displays its check results. If the NEC lo

Pagina 33 - TRANSFER TO THIRD PARTY

4-4 System Configuration Description of On-Screen Items and Key Usage Use the following keyboard keys to work with the SETUP utility. (Key functions

Pagina 34

System Configuration 4-5 Menu and Parameter Descriptions The SETUP utility has the following six major menus:  Main  Advanced  Stratus  Secur

Pagina 35 - ABOUT REPAIR PARTS

vii N8104-103 1000BASE-T Adapter ... 8-25 Supplement...

Pagina 36 - Advice for Your Health

4-6 System Configuration Available options in the Main and descriptions are listed below. Option Parameter Description Your Setting System Time HH:

Pagina 37 - Chapter 2

System Configuration 4-7 Keyboard Features Select "Keyboard Features" on the Main menu to display the following screen. See the table belo

Pagina 38 - STANDARD FEATURES

4-8 System Configuration Advanced Move the cursor onto "Advanced" to display the Advanced menu. Select an option with the "►" m

Pagina 39

System Configuration 4-9 Peripheral Configuration Select "Peripheral Configuration" on the Advanced menu to display the following screen.

Pagina 40

4-10 System Configuration Console Redirection Select "Console Redirection" on the Advanced menu to display the following screen. See the t

Pagina 41 - Free area

System Configuration 4-11 Stratus Move the cursor onto "Stratus" to display the Stratus menu. The Stratus menu screen contains no options

Pagina 42 - System with two CPU

4-12 System Configuration ft Memory Select "ft Memory" on the Stratus menu and press Enter to display the following screen. See the table

Pagina 43

System Configuration 4-13 Monitoring Configuration Select "Monitoring Configuration" on the Stratus menu to display the following screen.

Pagina 44 - 2-8 General Description

4-14 System Configuration Option Parameter Description Your Setting Boot Monitoring Time-out Period 1 - [10] - 20Specify the boot monitoring time-ou

Pagina 45 - Rear View

System Configuration 4-15 PCI OPROM hot key setup Select "PCI OPROM hot key setup" on the Stratus menu to display the following screen. Se

Pagina 46 - 2-10 General Description

viii (This page is intentionally left blank.)

Pagina 47

4-16 System Configuration Security Move the cursor onto "Security" to display the Security menu. Select "Set Supervisor Password"

Pagina 48

System Configuration 4-17 See the table below for setup options on the screen. Option Parameter Description Your Setting Set Supervisor Password Up

Pagina 49 - CD- ROM Drive

4-18 System Configuration Boot Move the cursor onto "Boot" to display the Boot menu. The server searches for the boot device according to t

Pagina 50

System Configuration 4-19 Exit Move the cursor onto "Exit" to display the Exit menu. The following describes each option on the Exit menu.

Pagina 51 - Chassis Board Layout

4-20 System Configuration  Get Default Value Select this option to restore all default values of the SETUP utility. The following screen appears:

Pagina 52

System Configuration 4-21 SCSI BIOS ∼ Fast!UTIL ∼ For several settings of the SCSI controller, the SCSI BIOS utility "Fast!UTIL" is used. T

Pagina 53 - PCI Module Status LED

4-22 System Configuration Start The procedure of starting Fast!UTIL is described below. Notes Note the following before starting Fast!UTIL.  Setti

Pagina 54 - LED Status / Action

System Configuration 4-23 Start Procedure Start Fast!UTIL in the procedure below: 1. Turn on the power of the server. The start message appears on a

Pagina 55

4-24 System Configuration 4. Select the proper adapter. IMPORTANT: The adapter "QLA12160 Ultra3 2400" is used for built-in hard disk. High

Pagina 56 - 2-20 General Description

System Configuration 4-25 Configuration Settings If you select "Configuration Settings" from the "Fast!UTIL Options" menu, the sc

Pagina 57 - General Description 2-21

Chapter 1 Precautions for Use This chapter includes information necessary for proper and safe operation of the server.

Pagina 58 - 2-22 General Description

4-26 System Configuration SCSI Device Settings If you put the cursor on "SCSI Device Settings" with keyboard cursors (↓ and ↑) in the "

Pagina 59

System Configuration 4-27 SCSI Bus Settings If you put the cursor on "SCSI Bus Settings" with keyboard cursors (↓ and ↑) in the "Confi

Pagina 60 - Green Amber Status / Action

4-28 System Configuration Autoconfigure SCSI Device If you put the cursor on "Autoconfigure SCSI Device" with keyboard cursors (↓ and ↑) in

Pagina 61 - SMM Board Status LED

System Configuration 4-29 Selectable Boot Settings If you put the cursor on "Selectable Boot Settings" with keyboard cursors (↓ and ↑) in t

Pagina 62 - 2-26 General Description

4-30 System Configuration Scan SCSI Bus If you select "Scan SCSI Bus" from the "Fast!UTIL Options" menu, the list of devices conn

Pagina 63 - PCI Slot Status LEDs

System Configuration 4-31 Exit Fast!UTIL ∼ Termination and Storage of Fast!UTIL ∼ After modifying the settings, press Esc several times to display th

Pagina 64 - BASIC OPERATION

4-32 System Configuration RESET AND FORCED SHUTDOWN Read this section if your server does not operate as expected, or if you want to resume all setup

Pagina 65

System Configuration 4-33 Clear CMOS / Password (Configuring Motherboard Jumpers) With the pre-installed SETUP utility, you can set desired passwords

Pagina 66 - Power ON

4-34 System Configuration (This page is intentionally left blank.)

Pagina 67 - Power OFF

Chapter 5 Installing and Using Utilities This section describes how to use the NEC EXPRESSBUILDER CD-ROM that comes with your server and to install t

Pagina 68 - Power-On Self Test (POST)

1-2 Precautions for Use WARNING LABELS Warning labels are placed in certain parts of the system so that the user stays alert to possible risks (Do no

Pagina 69

5-2 Installing and Using Utilities NEC EXPRESSBUILDER The NEC EXPRESSBUILDER, integrated setup software, can automatically detect the hardware conn

Pagina 70

Installing and Using Utilities 5-3  Inserting NEC EXPRESSBUILDER CD-ROM after Windows startup The "Master Control Menu" (see figure below

Pagina 71 - Floppy Disk Drive

5-4 Installing and Using Utilities NEC EXPRESSBUILDER Top Menu The NEC EXPRESSBUILDER top menu is used for the setup of hardware and the setup and

Pagina 72 - Insert/Remove Floppy Disk

Installing and Using Utilities 5-5 Setup The setup program is exclusively used for your server to perform automatic setup operations within the range

Pagina 73 - Use of Floppy Disk

5-6 Installing and Using Utilities Tools The Tools Menu is used to run the system diagnosis program or create the support disks. The items in the T

Pagina 74 - CD-ROM Drive

Installing and Using Utilities 5-7 Master Control Menu The Master Control Menu is used to:  Read documentation,  Install the management software,

Pagina 75 - Use of CD-ROM

5-8 Installing and Using Utilities NEC ESMPRO Agent AND Manager NEC Express5800/ft series system management applications "NEC ESMPRO Manager&q

Pagina 76 - 2-40 General Description

Installing and Using Utilities 5-9  Effects of using NEC ESMPRO Manager and NEC ESMPRO Agent NEC ESMPRO Manager and NEC ESMPRO Agent have sufficien

Pagina 77 - Chapter 3

5-10 Installing and Using Utilities Detection of Server Fault NEC ESMPRO Manager and NEC ESMPRO Agent detect errors causing faults to occur at an ear

Pagina 78 - DISK OPERATIONS

Installing and Using Utilities 5-11 Management of Server Operation Status NEC ESMPRO Agent manages and monitors a variety of components installed in

Pagina 79 - Disk Management

Precautions for Use 1-3 Label A Label B Label C Label D

Pagina 80

5-12 Installing and Using Utilities Monitoring (Management) of NEC Express5800/ft series NEC Express5800/ft series is a fault tolerant system. It can

Pagina 81

Installing and Using Utilities 5-13

Pagina 82

5-14 Installing and Using Utilities Collective Management of Distributed Servers The excellent GUI provided by NEC ESMPRO Manager allows servers on a

Pagina 83

Installing and Using Utilities 5-15  Data Viewer The data viewer indicates the server source configuration information in the Explorer format. In a

Pagina 84

5-16 Installing and Using Utilities NEC ESMPRO Agent NEC ESMPRO Agent is a utility which acts as an agent (proxy) between NEC Express5800/ft series a

Pagina 85

Installing and Using Utilities 5-17 Device name Device ID PCI module 2 PCI slot 1 on PCI module 2 PCI slot 2 on PCI module 2 PCI slot 3 on PCI modul

Pagina 86 - Importing Data Disks

5-18 Installing and Using Utilities Supplement Note the followings when using NEC ESMPRO Agent. Application log registered when system starting  S

Pagina 87

Installing and Using Utilities 5-19 CPU Installation Location If you select [ESMPRO] – [Hardware] – [CPU] in standard configuration with two CPUs, th

Pagina 88 - Extending Data Volume Size

5-20 Installing and Using Utilities Status Color after Mounting a Hard Disk Drive When creating a new mirror, the status of the hard disk and its upp

Pagina 89

Installing and Using Utilities 5-21 LAN Monitoring Threshold Because the NEC Express5800/ft series detects hardware faults on the network in the driv

Pagina 90

1-4 Precautions for Use CPU Module The figures below show locations of the labels on CPU module: Label BLabel CLabel A Label ALabel B Label C

Pagina 91 - Function

5-22 Installing and Using Utilities Change of SNMP Community If the security setting of the SNMP Service of a system, where the NEC ESMPRO Agent is i

Pagina 92

Installing and Using Utilities 5-23 Connection with Hard Disk Drive The preventive hard disk drive maintenance function may not work properly when a

Pagina 93 - Making disks duplex by RDR

5-24 Installing and Using Utilities When [FTServer] Tree Appears on Date Viewer in an Incorrect Manner If you open a Data Viewer immediately after th

Pagina 94

Installing and Using Utilities 5-25 NEC ESMPRO Manager To monitor and manage a computer, on which NEC ESMPRO Agent is installed, with a management PC

Pagina 95

5-26 Installing and Using Utilities Monitoring CPU Module To monitor the CPU modules and the components on the CPU module, see the [CPU Module] tree.

Pagina 96

Installing and Using Utilities 5-27  Update Allows the device identification information of the CPU modules to be viewed and BIOS of the CPU module

Pagina 97

5-28 Installing and Using Utilities  DIMM Allows the information of DIMM on the CPU modules to be viewed.

Pagina 98 -  Dynamic disk

Installing and Using Utilities 5-29 Monitoring PCI Module To monitor the PCI modules (including expansion PCI modules) and the components on the PCI

Pagina 99

5-30 Installing and Using Utilities  Maintenance Allows the start/stop, MTBF information clear, and diagnosis of the PCI modules to be provided. Se

Pagina 100

Installing and Using Utilities 5-31 Monitoring PCI Slots and Devices on PCI Module To monitor the PCI slots and devices on the PCI modules (including

Pagina 101 - How to Locate Failed Disks

Precautions for Use 1-5 PCI Module The figures below show locations of the labels on PCI module: External ViewLabel BLabel AInternal ViewLabel C

Pagina 102

5-32 Installing and Using Utilities  PCI Device – General Allows the information of devices on the PCI slot to be viewed.  PCI Device – Detail

Pagina 103

Installing and Using Utilities 5-33  PCI Bridge – General Allows the information of bridges on the PCI bus to be viewed  PCI Bridge – Bus Allows

Pagina 104

5-34 Installing and Using Utilities  PCI Bridge – Detail Allows the detailed information of a bridge on the PCI bus to be viewed.

Pagina 105 - IMPORTANT:

Installing and Using Utilities 5-35 Monitoring SCSI Enclosure To monitor the SCSI enclosure, see the [SCSI enclosure] tree. To see the information on

Pagina 106

5-36 Installing and Using Utilities  Maintenance Allows the MTBF information of the SCSI adapter to be viewed or cleared. See "Maintenance of

Pagina 107

Installing and Using Utilities 5-37  Electronics – General Allows the configuration and other information of the SCSI enclosure electronics to be v

Pagina 108

5-38 Installing and Using Utilities  SCSI Slot – General Allows the configuration and other information of the SCSI slot to be viewed. IMPORTANT: Y

Pagina 109 - CHANGE DRIVE LETTER

Installing and Using Utilities 5-39 Monitoring Mirror Disk To monitor the mirror disk components, see the [Mirror Disk] tree. To view information on

Pagina 110 - DUAL LAN CONFIGURATION

5-40 Installing and Using Utilities Monitoring Hard Disk To monitor the hard disks and detect disk failures at an early stage, use the NEC ESMPRO Man

Pagina 111

Installing and Using Utilities 5-41 2. Confirmation of mirror status To check the redundancy status of the failed mirror disk, open [Mirror Disk] sc

Pagina 112 - 6. Click [OK]

PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs and related materials, is the valuable

Pagina 113 - Removing dual LAN

1-6 Precautions for Use Label ALabel BLabel C

Pagina 114

5-42 Installing and Using Utilities IMPORTANT: The Mirror Disk screen shows a pair of hard disks constructing mirroring as a mirror. Note that when m

Pagina 115

Installing and Using Utilities 5-43 3. Recovery from a hard disk failure If a hard disk breaks, the broken disk must be replaced immediately. This s

Pagina 116 - MODULES

5-44 Installing and Using Utilities IMPORTANT: The status color of the SCSI slot differs depending on the connection of mirrored hard disks:  If on

Pagina 117

Installing and Using Utilities 5-45 When the hard disk is connected, SCSI Slot changes the status to "Normal". [SCSI Slot] → [General] Als

Pagina 118

5-46 Installing and Using Utilities Maintenance of NEC Express5800/ft series NEC Express5800/ft series maintenance can be done in two ways; one is to

Pagina 119

Installing and Using Utilities 5-47 The table below shows the component-specific maintenance functions executable from NEC ESMPRO. Dump acquisition D

Pagina 120

5-48 Installing and Using Utilities Start and Stop of Components To start or stop a component with NEC ESMPRO Manager, use the [Maintenance] tree of

Pagina 121

Installing and Using Utilities 5-49 Procedure in NEC ESMPRO Manager Start 1. Select the target component in the [FTServer] tree. 2. Check the curre

Pagina 122

5-50 Installing and Using Utilities Sample screen of NEC ESMPRO Manager 2 [Maintenance] screen of CPU module [CPU Module] – [CPU Module] - [Maintena

Pagina 123 - CONFIGURATION

Installing and Using Utilities 5-51 Procedure in the ft server utility Start 1. Select the target component by using the ft server utility. 2. Chec

Pagina 124

Precautions for Use 1-7 Expansion PCI Module The figure below shows locations of the labels on expansion PCI module: External ViewLabel BLabel AInte

Pagina 125 - Chapter 4

5-52 Installing and Using Utilities Check and Clear of MTBF Information The MTBF information of a component can be viewed or cleared (initialized). N

Pagina 126 - SYSTEM BIOS ~ SETUP ~

Installing and Using Utilities 5-53 MTBF clear Component Remote Local SCSI Enclosure To start the module/component forcibly after replacing a module

Pagina 127 - Starting SETUP Utility

5-54 Installing and Using Utilities Procedure in the ft server utility Perform the procedure below before replacement of a component. 1. Select the

Pagina 128

Installing and Using Utilities 5-55 Diagnostics The NEC Express5800/ft series provides the self-check diagnosis function for some components. If a fa

Pagina 129

5-56 Installing and Using Utilities Procedure in NEC ESMPRO Manager 1. Select the target component in the [FTServer] tree. 2. Check the current sta

Pagina 130

Installing and Using Utilities 5-57 Procedure in the ft server utility 1. Select the target component by using the ft server utility. 2. Check the

Pagina 131

5-58 Installing and Using Utilities Firmware Update NEC Express5800/ft series can update firmware (including BIOS) if some hardware components operat

Pagina 132 - Advanced

Installing and Using Utilities 5-59 Procedure in NEC ESMPRO Manager 1. Save the image data of the update firmware in an arbitrary directory of the N

Pagina 133 - Peripheral Configuration

5-60 Installing and Using Utilities 6. After the BIOS for a single CPU module is completed, click the [Jump Switch] button. The module completely up

Pagina 134 - Console Redirection

Installing and Using Utilities 5-61 Procedure in ft server utility 1. Save the image data of the update firmware in a desired directory of the NEC E

Pagina 135 - Stratus

1-8 Precautions for Use Label ALabel BLabel C

Pagina 136

5-62 Installing and Using Utilities 7. After the BIOS for a single CPU module is completed, click the [Jump Switch] button. The module completely up

Pagina 137 - Monitoring Configuration

Installing and Using Utilities 5-63 Dump Collection To collect the dump file with NEC ESMPRO Manager, use [CPU Module] →[Maintenance] tree in the dat

Pagina 138

5-64 Installing and Using Utilities Procedure in NEC ESMPRO Manager The [Dump] button of NEC ESMPRO Manager performs the function of "saving dum

Pagina 139 - PCI OPROM hot key setup

Installing and Using Utilities 5-65 Procedure in ft server utility 1. Select the target CPU module by using the ft server utility. 2. Check the cur

Pagina 140 - Security

5-66 Installing and Using Utilities SCSI Bus Reset The SCSI bus can be reset. Select [FTServer] tree→[PCI Module]→[SCSI adapter]→[SCSI bus] screens w

Pagina 141 - System Configuration 4-17

Installing and Using Utilities 5-67 Setup of Preventive Disk Maintenance In this section, the preventive disk maintenance (S.M.A.R.T.) is configured.

Pagina 142

5-68 Installing and Using Utilities Setup of System Operation The following properties can be set as the operation setup of the whole system.  Quic

Pagina 143 -  Save Changes & Exit

Installing and Using Utilities 5-69 Configure the system settings using the ft server utility in the following procedure. The system cannot be config

Pagina 144 -  Save Changes

5-70 Installing and Using Utilities Refresh of View based on State Change Alert Setting A new function is supported so that NEC ESMPRO Manager window

Pagina 145 - SCSI BIOS ∼ Fast!UTIL ∼

Installing and Using Utilities 5-71 BMC Firmware Update The firmware of the BMC on the PCI module can be updated. The BMC firmware can be updated by

Pagina 146

Precautions for Use 1-9 PRECAUTIONS FOR SAFETY This section provides precautions for using the server safely. Read this section carefully to ensure p

Pagina 147

5-72 Installing and Using Utilities 2. Enter the location to store the new firmware, and click [Activate]. [Confirmation] dialog box appears. 3. C

Pagina 148

Installing and Using Utilities 5-73 SMM Firmware Update The firmware of the SMM on the PCI module can be updated. The SMM firmware can be updated by

Pagina 149 - Configuration Settings

5-74 Installing and Using Utilities Procedure of Update from ft server utility Update the firmware in the following procedure. 1. Click [Firmware] →

Pagina 150

Chapter 6 Maintenance This chapter describes the daily maintenance of NEC Express5800/ft series and precautions when relocating or storing the server

Pagina 151

6-2 Maintenance DAILY MAINTENANCE To use your NEC Express5800/ft series in best condition, check and maintain regularly as described below. If an err

Pagina 152 - – Sync Period

Maintenance 6-3 Checking STATUS LEDs Check the LED indication on the front of the NEC Express5800/ft series or on hard disks installed in 3.5-inch ha

Pagina 153

6-4 Maintenance Cleaning Clean the server on a regular basis to keep the server in a good shape. WARNING Observe the following instructions to use

Pagina 154 - Select Host Adapter

Maintenance 6-5 Cleaning the Keyboard and Mouse IMPORTANT: A keyboard and a mouse use USB interface. Therefore it is not necessary to power off the s

Pagina 155 - Return to Fast!UTIL

6-6 Maintenance Cleaning CD-ROM A dusty CD-ROM or dust-accumulated tray causes the device to fail to read data correctly. Follow the procedure below

Pagina 156 - RESET AND FORCED SHUTDOWN

Maintenance 6-7 SYSTEM DIAGNOSTICS (CONSUMER) The System Diagnostics (Consumer) runs several tests on the server. Select [Tools] → [System Diagnostic

Pagina 157

1-10 Precautions for Use CAUTION Prevent water or foreign objects from getting into the equipment. Do not let water or foreign objects (e.g., p

Pagina 158 - 4-34 System Configuration

6-8 Maintenance 6. Select [System Diagnostics] and then select [System Diagnostics (Consumer)]. CURSOR: Select Window ENTER: View Window P: Log

Pagina 159 - Chapter 5

Maintenance 6-9 OFF-LINE MAINTENANCE UTILITY The Off-line Maintenance Utility is not included in your NEC EXPRESSBUILDER CD-ROM.

Pagina 160 - NEC EXPRESSBUILDER

6-10 Maintenance RELOCATING/STORING THE NEC Express5800/ft series Follow the procedure below to relocate or store the server. (Users should not attem

Pagina 161

Maintenance 6-11 8. Protect the server with the shock-absorbing materials, and pack it securely. IMPORTANT: Check and adjust the system clock befor

Pagina 162 - NEC EXPRESSBUILDER Top Menu

6-12 Maintenance (This page is intentionally left blank.)

Pagina 163

Chapter 7 Troubleshooting If the product does not work properly, see this chapter before deciding that it is a breakdown.

Pagina 164

7-2 Troubleshooting TO LOCATE THE ERRORS Use NEC ESMPRO to monitor the occurrence of fault during the system operation. Especially take note on wheth

Pagina 165 - Master Control Menu

Troubleshooting 7-3 ERROR MESSAGES If the NEC Express5800/ft series enters the abnormal state, the error is posted by various means. This section exp

Pagina 166 - NEC ESMPRO Agent AND Manager

7-4 Troubleshooting Windows Server 2003, Enterprise Edition Error Messages If a fatal error (e.g., a STOP or system error) occurs after Windows Serve

Pagina 167

Troubleshooting 7-5 Server Management Application Error Message If the server management tool such as NEC ESMPRO Agent, NEC ESMPRO Manager, or GAMSer

Pagina 168 - Prevention of Server Fault

Precautions for Use 1-11 Use of Power Supply and Power Cord WARNING Do not handle a power plug with a wet hand. Do not plug/unplug a power cord w

Pagina 169

7-6 Troubleshooting SOLVING PROBLEMS When the server fails to operate as expected, see the following to find out your problem and follow the given in

Pagina 170

Troubleshooting 7-7 "Display Settings" on the bottom-right of the window: → Select [Control Panel] – [Display] - [Settings] tab, and chang

Pagina 171

7-8 Troubleshooting Fail to access to internal or external devices:  Are cables properly connected? → Make sure that the interface cables and power

Pagina 172 -  Operation Window

Troubleshooting 7-9 The keyboard or mouse fails to operate:  Is the cable properly connected? → Make sure that the cable is connected to the correc

Pagina 173 -  Alert Viewer

7-10 Troubleshooting Fail to access to the CD-ROM:  Is the CD-ROM properly set in the CD-ROM drive tray? → The tray is provided with a holder to se

Pagina 174 - NEC ESMPRO Agent

Troubleshooting 7-11 The system does not operate according to the configured settings of "Automatic Restart" at the occurrence of error. →

Pagina 175

7-12 Troubleshooting Perflib-related logs are recorded in the application event log when system starting: → When system is starting, Perflib log may

Pagina 176 - Supplement

Troubleshooting 7-13 Event ID: 16 Description: Team #X: The last adapter has lost link. Network connection has been lost.” “Source: iANSMiniport

Pagina 177

7-14 Troubleshooting Failure in CPU module duplication and the following event is logged: → If the simultaneous replacement of the CPU and PCI modul

Pagina 178

Troubleshooting 7-15 "Stratus Fault Tolerant Virtual 69000 Video" is displayed on "Remove Hardware" dialog box: → If you double-

Pagina 179

1-12 Precautions for Use Installation, Relocation, Storage and Connection WARNING Disconnect the power cord(s) before installing or removing the eq

Pagina 180

7-16 Troubleshooting CPU load ratio of SNMP Service (snmp.exe) increases: → While monitoring the server from NEC ESMPRO Manager, the CPU load ratio

Pagina 181

Troubleshooting 7-17 Disk Management displays disks that cannot be used: → Follow the instruction below: Disk status Description Action When

Pagina 182

7-18 Troubleshooting Memory dump (debug information) cannot be collected at a failure occurrence:  Is there enough space at memory dump (debug inf

Pagina 183 - NEC ESMPRO Manager

Troubleshooting 7-19 Problems with NEC EXPRESSBUILDER When the server is not booted from the NEC EXPRESSBUILDER CD-ROM, check the following:  Did yo

Pagina 184 -  Maintenance

7-20 Troubleshooting Problems with Master Control Menu Failed to read online documentation  Is Adobe Acrobat Reader installed properly? → A par

Pagina 185 -  Update

Troubleshooting 7-21 Problems with NEC ESMPRO NEC ESMPRO Manager → See Chapter 5. See also online document in NEC EXPRESSBUILDER CD-ROM for troubles

Pagina 186 -  DIMM

7-22 Troubleshooting 3. Click [OK] to terminate the operation. To allow NEC ESMPRO Agent to receive SNMP packets sent from NEC ESMPRO Manager, set t

Pagina 187

Troubleshooting 7-23 Clicking the [No] button does not cause the tree to be reconstructed in the data viewer. If so, the information in the data view

Pagina 188

7-24 Troubleshooting This cannot indicate whether the NEC ESMPRO Agent machine is shut down or entered into the sleep state. Keep these in mind when

Pagina 189

Troubleshooting 7-25 7. Confirm that "ESMCommonService" is active and close the [Service] and [Control Panel]. Change the thresho

Pagina 190 -  PCI Device – Detail

Precautions for Use 1-13 Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or alter the server. Unless described here

Pagina 191 -  PCI Bridge – Bus

7-26 Troubleshooting [ft Server] Tree Appears on Date Viewer in an Incorrect Manner: → If you open a Data Viewer immediately after the system starts

Pagina 192 - PCI Bridge – Detail

Troubleshooting 7-27 A modular state is displayed as "fault": → PCI modules, SCSI adapters, SCSI buses, and modules under the SCSI enclosu

Pagina 193

7-28 Troubleshooting The information on the hard disk drive in the Disk Expansion Unit is not displayed correctly. → When the Disk Expansion Unit is

Pagina 194

Troubleshooting 7-29 COLLECTION OF TROUBLE LOGS In the event of trouble, you can get information in the procedures described below: IMPORTANT:  Yo

Pagina 195 -  Electronics – Maintenance

7-30 Troubleshooting Collection of Event Logs Collect the logs of various events that have occurred in the NEC Express5800/ft series. IMPORTANT: If a

Pagina 196 -  SCSI Slot – General

Troubleshooting 7-31 Collection of Configuration Information Collect information such as the hardware configuration and internal setting information

Pagina 197 - [Mirror Disk]

7-32 Troubleshooting COLLECTION OF THE MEMORY DUMP If a failure occurs, the memory data should be dumped to acquire the required information. If you

Pagina 198 - [General]

Troubleshooting 7-33 Saving Dump Files Press the DUMP switch to save the dump file when an error occurs. Insert a metal pin (a straightened large pap

Pagina 199

7-34 Troubleshooting (This page is intentionally left blank.)

Pagina 200

Chapter 8 Option This chapter describes option devices available and procedures to add options and replace failed components. IMPORTANT:  Optional

Pagina 201

1-14 Precautions for Use During Operation CAUTION Do not pull out a device during operation. Do not pull out or remove a device while it works. T

Pagina 202 - [Alert report]

8-2 Option SAFETY PRECAUTIONS Observe the following notes to install or remove optional devices safely and properly. WARNING Observe the following

Pagina 203

Option 8-3 ANTI-STATIC MEASURES The server contains electronic components sensitive to static electricity. Avoid failures caused by static electricit

Pagina 204

8-4 Option PREPARING YOUR SYSTEM FOR UPGRADE Note the followings, when installing or replacing devices, to improve the performance of NEC Express5800

Pagina 205 - ESMPRO

Option 8-5 OPTIONS The following table lists options available for NEC Express5800/ft series. Any other options not described in this table are maint

Pagina 206 - Start and Stop of Components

8-6 Option 3.5-INCH HARD DISK DRIVE The 3.5-inch hard disk drive bay in front of the server contains six slots in which hard disks with the SCA2 inte

Pagina 207

Option 8-7 NOTES:  POWER LED is on to indicate that it is the primary module.  The module that you plug in first will be the primary module. Yo

Pagina 208

8-8 Option Installing 3.5-inch Hard Disk Drive Follow the procedure below to install the hard disk. A hard disk may be installed in another slot in t

Pagina 209

Option 8-9 6. Unlock the hard disk drive to be added. 7. Firmly hold the handle of the hard disk to install and insert the hard disk into the slot

Pagina 210

8-10 Option 8. Slowly close the lever. When the lever is locked, you will hear a click sound. IMPORTANT: Be careful not to pinch your finger(s) betw

Pagina 211 - 4. Start the component

Option 8-11 Removing 3.5-inch Hard Disk Drive Follow the procedure below to remove the hard disk. IMPORTANT:  Make sure to read "Anti-static

Pagina 212

Precautions for Use 1-15 Rack-mount Model WARNING Do not use the equipment in an unsuitable place. Do not install a server rack in an unsuitable

Pagina 213 - Diagnostics

8-12 Option Replacing 3.5-inch Hard Disk Drive Follow the procedure below to remove the failed hard disk. If the hard disk fails, it should be replac

Pagina 214 - [PCI Module] – [Maintenance]

Option 8-13 PROCESSOR Install a CPU in a CPU socket on the CPU module that is to be installed in the NEC Express5800/ft series. The CPU module has fo

Pagina 215

8-14 Option DIMM Install DIMMs (Dual Inline Memory Module) in DIMM sockets on the CPU module that is to be installed in the NEC Express5800/ft series

Pagina 216 - Firmware Update

Option 8-15 PCI BOARD PCI module and expansion PCI module can contain three PCI boards. The PCI slot #1 of the upper two PCI modules contains a facto

Pagina 217 - [CPU Module] – [Update]

8-16 Option SETUP OF OPTIONAL PCI BOARD IMPORTANT:  NEC recommends that you request a maintenance engineer of your service representative having t

Pagina 218

Option 8-17 N8804-001P1 100BASE-TX Adapter Set Slots to install the board IMPORTANT: Note the following about this product: For LAN cable’s connect

Pagina 219 - [CPU Module]

8-18 Option 2. Build a dual LAN configuration. (See "Set Dual LAN Configuration" in the separate volume of User’s Guide (Setup).) IMPORTAN

Pagina 220

Option 8-19 N8803-031F Fibre Channel Controller Slots to install the board PCI slot for PCI module PCI slot for expansion PCI module Group 1 Group 2

Pagina 221 - Dump Collection

8-20 Option 4. Select [SCSI and RAID controllers], and then click [Next]. 5. Do not select a driver listed on the model list. Click [Have Disk…]

Pagina 222 - [CPU Module] – [Maintenance]

Option 8-21 8. A warning message tells that you are about to update a driver. Click [Yes] to continue. The driver will be installed. * During th

Pagina 223

Keep this User's Guide handy for quick reference when necessary. SAFETY INDICATIONS To use NEC Express5800 Series safely, follow the instruction

Pagina 224 - SCSI Bus Reset

1-16 Precautions for Use CAUTION Do not leave two or more devices pulled out from the rack. If you pull out two or more devices the rack may fall

Pagina 225

8-22 Option 10. Select [Control Panel] – [Administrative Tools]- [Computer Management] – [Device Manager], and confirm that there are as many [Qlogi

Pagina 226 - Setup of System Operation

Option 8-23 N8104-84 1000BASE-SX Adapter Consult your sales personnel for details when purchasing this hardware. IMPORTANT: Note the following about

Pagina 227

8-24 Option 1. Mount the N8104-84 adapter to the slot with the same number in PCI module or expansion PCI module, and then start the Windows Server

Pagina 228

Option 8-25 N8104-103 1000BASE-T Adapter Consult your sales personnel for details when purchasing this hardware. IMPORTANT: Note the following about

Pagina 229 - BMC Firmware Update

8-26 Option 1. Mount the N8104-103 adapter to the slot with the same number in PCI module or expansion PCI module, and then start the Windows Server

Pagina 230 - 3. Click [OK]

Option 8-27 Supplement Before using backup devices: If any of following backup devices is used for internal SCSI connector of NEC Express5800/ft seri

Pagina 231 - SMM Firmware Update

8-28 Option (This page is intentionally left blank.)

Pagina 232

Appendix A Specifications NEC Express5800/340Hb-R Item N8800-047F N8800-073F Type Intel® Xeon™ Processor MP Clock/L3 cache 2.80GHz/2MB 3.00GHz/4MB

Pagina 233 - Chapter 6

A-2 Specifications *1: A factory-installed 18.1GB hard disk drive in slot #1 cannot be replaced. Use the factory-set configuration. Modifications to

Pagina 234 - DAILY MAINTENANCE

Appendix B IRQ and I/O Port Address The factory-set interrupt requests and I/O port addresses are listed below. Interrupt Request The factory-set IR

Pagina 235 - Making Backup Copies

Precautions for Use 1-17 For Proper Operation Observe the following instructions for successful operation of the server. Failure to observe them coul

Pagina 236 - Cleaning

B-2 IRQ and I/O Port Address I/O Port Address The factory-set I/O port addresses for the server are assigned as follows: Address Device 0x00000000

Pagina 237 - Bottom View

IRQ and I/O Port Address B-3 Address Device 0x000003C0 – 0x000003DF Stratus Fault Tolerant PCI to PCI bridge 0x000003C0 – 0x000003DF VGA Display

Pagina 238

B-4 IRQ and I/O Port Address (This page is intentionally left blank.)

Pagina 239 - Test Items

1-18 Precautions for Use  It is recommended to use NEC's genuine option products. Some competitors’ products are compatible with this server.

Pagina 240 - Target scope

Precautions for Use 1-19 TRANSFER TO THIRD PARTY When you transfer (or sell) the product or its included items, you must observe the following: Serv

Pagina 241 - OFF-LINE MAINTENANCE UTILITY

1-20 Precautions for Use DISPOSAL OF EQUIPMENT AND CONSUMABLES  When you dispose of the main unit, hard disk drive, floppy disks, CD-ROMs, optional

Pagina 242

Precautions for Use 1-21 IF SYSTEM TROUBLE IS SUSPECTED Before sending the equipment for repair, try the following: 1. Check if its power cord and c

Pagina 243

1-22 Precautions for Use Advice for Your Health Prolonged use of a computer may affect your health. Keep in mind the following to reduce stresses o

Pagina 244 - 6-12 Maintenance

Chapter 2 General Description This chapter describes what you need to know to use the NEC Express5800/ft series. Refer to this chapter when you want

Pagina 245 - Chapter 7

2-2 General Description STANDARD FEATURES High performance ・ Intel® Xeon™ Processor MP ・ High-speed Ethernet interface (1000Mbps/100Mbps/10Mbps s

Pagina 246 - TO LOCATE THE ERRORS

General Description 2-3 The NEC Express5800/ft series achieves fault-tolerant high-availability in a space-saving form factor by incorporating redund

Pagina 247 - ERROR MESSAGES

SYMBOLS USED IN THIS USER'S GUIDE AND WARNING LABELS Attention Indicates a risk of an electric shock. Indicates a risk of an injury due to hea

Pagina 248 - 1. Add a physical memory

2-4 General Description NEC Express5800/ft series mainly provides the following advantages:  Highly fault-tolerant processing and I/O subsystems NE

Pagina 249

General Description 2-5  Local and remote management NEC Express5800/ft series uses NEC ESMPRO as a server management tool. This tool uses a GUI th

Pagina 250 - SOLVING PROBLEMS

2-6 General Description HOW THE OPERATING SYSTEM SEES THE CPU MODULES On NEC Express5800/ft series, the CPU modules are redundantly configured but on

Pagina 251 -  Is the memory size large?

General Description 2-7 NAMES AND FUNCTIONS OF COMPONENTS Names and functions of components are shown below: Front View (with Front Bezel Removed)

Pagina 252

2-8 General Description 1 PCI module 10 (for group 1) A module that includes a PCI board, LAN controller, SCSI controller, and SMM board. 2 PCI mo

Pagina 253

General Description 2-9 Rear View 7 8 9 10 11 12 13 14 15 1622 21 20 19 1822 21 20 19 18171 PCI module 10 (for Group 1) 2 PCI module 11 (for Grou

Pagina 254

2-10 General Description 1 Serial port 1 (A) connector Connected to a device that has a serial interface. For maintenance use only. 2 Serial port

Pagina 255

General Description 2-11 CPU Module 1 2 3456 Group 1 and group 2 have the same configuration. 1 Power unit 2 CPU module board 3 DIMM 4 CPU (pro

Pagina 256

2-12 General Description PCI Module 12 346 76 8 5 Group 1 and group 2 have the same configuration. 1 Power unit 2 AC inlet (in the rear) 3 Backp

Pagina 257

General Description 2-13 CD- ROM Drive 1 2 3 1 Access LED An LED that stays on while the loaded CD-ROM is accessed. 2 CD tray eject button A

Pagina 258

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These

Pagina 259

2-14 General Description Expansion PCI Module 12346 6 5 1 Power unit 2 AC inlet (in the rear) 3 Backpanel connector (in the rear) 4 PCI board slo

Pagina 260

General Description 2-15 Chassis Board Layout Clock board Interface boardBack panel

Pagina 261

2-16 General Description LEDs This section describes indications and meanings of the LEDs on NEC Express5800/ft series. POWER LED The POWER switch

Pagina 262

General Description 2-17 PCI Module Status LED FRONT POWER LED Hard Disk Drive LED BMC Status LED Disk Access LED PCI Module Status LED REAR LAN

Pagina 263

2-18 General Description BMC Status LED The BMC Status LED indicates the status of the Baseboard Management Controller (BMC) installed on NEC Express

Pagina 264 -  Is Shift pressed?

General Description 2-19 PCI Module Status LEDs (1 and 2) Disk Access LED The PCI module has three LEDs. Combined, the three LEDs show the status of

Pagina 265 - Problems with NEC ESMPRO

2-20 General Description PCI#1 PCI#2 Status LED 2 DISK Access LED Status LED 2DISK Access LED Description Action Green Green/Off * Amber Green/Off *

Pagina 266

General Description 2-21 (2) Status LED 1 of both PCI modules are red PCI#1 PCI#2 Status LED 2 DISK AccessLEDStatus LED 2 DISK Access LED Descripti

Pagina 267

2-22 General Description PCI#1 PCI#2 Status LED 2 DISK Access LED Status LED 2DISK Access LED Description Action Green Off Off Off The PCI modul

Pagina 268

General Description 2-23 DISK LED A DISK LED shows the status of a hard disk that is mounted in a slot of the 3.5-inch hard disk drive bay. Combined,

Pagina 269

Trademarks NEC EXPRESSBUILDER, NEC ESMPRO, and NEC Express5800/ft series are trademarks of NEC Corporation. Stratus is a registered trademark of Stra

Pagina 270

2-24 General Description PCI Slot Status LED The PCI module has three PCI Slot Status LEDs to indicate the status of PCI slot. The expansion PCI modu

Pagina 271

General Description 2-25 SMM Board Status LED SMM Board Status LED indicates the status of SMM board. Red Amber / Green Status / Action On Off The

Pagina 272

2-26 General Description Expansion PCI Module Status LED Expansion PCI Module Status LED Expansion PCI Module Status LEDPCI Slot Status LED (SLOT

Pagina 273 - COLLECTION OF TROUBLE LOGS

General Description 2-27 PCI Slot Status LEDs To show the status of PCI board slots, each PCI module has three status LEDs. LED Status / Action Red (

Pagina 274 - Collection of Event Logs

2-28 General Description BASIC OPERATION This section explains the basic operation of the NEC Express5800/ft series. Installing/Removing the Front B

Pagina 275 - 4. Click [Save]

General Description 2-29 Removal 1. If the rack has a front door, open the front door. 2. Hold both ends of the front bezel, pull them out together

Pagina 276 - Preparing for Memory Dump

2-30 General Description Power ON To power on NEC Express5800/ft series, press the POWER switch located on the front panel. Follow the steps below to

Pagina 277 - Saving Dump Files

General Description 2-31 Power OFF Follow the steps below to turn off the power. If NEC Express5800/ft series is plugged to a UPS, see manuals includ

Pagina 278 - 7-34 Troubleshooting

2-32 General Description Power-On Self Test (POST) Power-On Self Test (POST) is a self-test function stored on the motherboard of NEC Express5800/ft

Pagina 279 - Chapter 8

General Description 2-33 Flow of POST This section walks you through how POST is performed. 1. When you power on the system, one selected CPU/PCI mo

Pagina 280 - SAFETY PRECAUTIONS

i PREFACE Welcome to the NEC Express5800/ft series. NEC Express5800/ft series is a "fault-tolerant (ft)" server focusing on "high relia

Pagina 281 - ANTI-STATIC MEASURES

2-34 General Description 7. Upon completion of POST, the password entry screen appears prior to OS startup. The password entry screen will appear af

Pagina 282

General Description 2-35 Floppy Disk Drive A USB floppy disk drive is attached to the main unit. It allows you to read and write (save) data using fl

Pagina 283 - OPTIONS

2-36 General Description Insert/Remove Floppy Disk Before inserting a floppy disk into the drive, make sure that NEC Express5800/ft series is on and

Pagina 284 - 3.5-INCH HARD DISK DRIVE

General Description 2-37 Use of Floppy Disk You may need to store important data on floppy disks. Since the floppy disk is a very delicate medium, yo

Pagina 285 - NOTES:

2-38 General Description CD-ROM Drive NEC Express5800/ft series has a CD-ROM drive on the front panel. It is a device used to read data from a CD-ROM

Pagina 286

General Description 2-39 Use of CD-ROM Observe the following when you use a CD-ROM on NEC Express5800/ft series:  As for a disk such as a noncompli

Pagina 287

2-40 General Description (This page is intentionally left blank.)

Pagina 288 - 8. Slowly close the lever

Chapter 3 Windows Setup and Operation This chapter describes setup procedures to make NEC Express5800/ft series ready for use.

Pagina 289 - 1. Remove the front bezel

3-2 Windows Setup and Operation DISK OPERATIONS NEC Express5800/ft series duplicates disks to secure data by using “Disk Management” or the “Rap

Pagina 290

Windows Setup and Operation 3-3 Disks Operations Using Disk Management Disk Management NEC Express5800/ft series (which does not support the RDR f

Pagina 291 - PROCESSOR

ii ABOUT THIS USER'S GUIDE This User's Guide helps a user to properly setup and use the product. Consult this guide to ensure safety as well

Pagina 292

3-4 Windows Setup and Operation The pairs of mirror disks as shown above can be created by selecting hard disks whose target IDs are identical in t

Pagina 293 - PCI BOARD

Windows Setup and Operation 3-5 Configuring and Breaking Mirror This section describes the procedures to configure and break the mirror of hard di

Pagina 294 - SETUP OF OPTIONAL PCI BOARD

3-6 Windows Setup and Operation 4. Select and right-click a disk, and then execute [Convert to Dynamic Disk…]. On the [Convert to Dynamic Disk]

Pagina 295

Windows Setup and Operation 3-7 IMPORTANT:  Clicking [Add Mirror] displays the [Logical Disk Manager] dialog box, but there is no problem. Click

Pagina 296

3-8 Windows Setup and Operation Confirming if Paired Disks are Mirrored Properly Check the following to confirm that the mirror is configured prop

Pagina 297 - Installation of driver

Windows Setup and Operation 3-9 Breaking mirror Follow the procedures below to break the mirror of volumes. The procedures to break a mirror on C

Pagina 298

3-10 Windows Setup and Operation Importing Data Disks This section describes a procedure to import a data disk using Disk Management. IMPORTANT:

Pagina 299 - 9. Click [Finish]

Windows Setup and Operation 3-11 5. In the [Foreign Disk Volumes] dialog box, check the volumes to import, and click [OK]. 6. The disk im

Pagina 300 - How to confirm the status:

3-12 Windows Setup and Operation Extending Data Volume Size This section describes a procedure to extend a volume size using Disk Management.

Pagina 301 - N8104-84 1000BASE-SX Adapter

Windows Setup and Operation 3-13 4. On the [Select Disks] dialog box, enter the amount of space to extend and click [Next]. (In this case, 1500MB

Pagina 302

iii Additional symbols The following symbols are used throughout this User's Guide in addition to the caution symbols describe at the beginning.

Pagina 303 - N8104-103 1000BASE-T Adapter

3-14 Windows Setup and Operation 7. Configure the mirror of the extended volume.

Pagina 304

Windows Setup and Operation 3-15 Disk Operations Using the RDR (Rapid Disk Resync) Function RDR (Rapid Disk Resync) Models supporting the RDR func

Pagina 305

3-16 Windows Setup and Operation 3. RDR can be set only to basic disks. If a span volume or stripe volume is needed, make settings of RDR to a b

Pagina 306 - 8-28 Option

Windows Setup and Operation 3-17 [Left frame] The tree shows disks inserted to the built-in slots and virtual disks (RDR Virtual Disks) created by

Pagina 307 - Appendix A

3-18 Windows Setup and Operation 2. From [Start], select [Control Panel] then [Administrative Tools] and start [Computer Management]. On the tree

Pagina 308 - A-2 Specifications

Windows Setup and Operation 3-19 IMPORTANT: When RDR is set to a disk containing the boot partition, the following pop-up message appears, and cli

Pagina 309 - Appendix B

3-20 Windows Setup and Operation 7. Click [Logical Disk Information] and then [RDR Virtual Disk x](x=1,2,3) to confirm that the synchronization is

Pagina 310 - I/O Port Address

Windows Setup and Operation 3-21  When the disk where RDR is set is converted to a dynamic disk, the area which has not been synchronized (the ar

Pagina 311

3-22 Windows Setup and Operation Removing duplex configuration of RDR disks This section describes how to remove duplex configuration from the di

Pagina 312

Windows Setup and Operation 3-23 5. Remove the RDR setting from the disk in the corresponding slot (the Slot 2 of the Group2) in the same manner.

Comentarios a estos manuales