CONFIGURATION GUIDE – NEC Express5800/R120d-2M
NEC Corporation Revision 1.0, March 2012 23
4.2.6 Up to sixteen Drives with RAID 5/6 Controller with 512 MB Cache
Product Name / Description
Storage Controller
Required
RAID Controller (512MB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 512MB, Int. 8, PCIe 2.0 x8, SAS 6Gb/s,
SATA 6Gb/s
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
Internal SAS/SATA Cable
1 x mini-SAS to 1 x mini-SAS, 6 sets
2.5-inch HDD Cage
8 x 2.5-inch hot plug drive bays
Optional Drive
Cage
Required
2.5-Inch HDD Cage
8 x 2.5-inch hot plug drive bays
Including six sets of 1 x mini-SAS to 1 x mini-SAS cable, SAS
expander card
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
73.2GB 15K Hot Plug 2.5-inch SAS HDD
1x 73.2 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
100GB Hot Plug 2.5-inch SAS SSD
1 x 100 GB SAS SSD, 2.-inch, 6Gb/s
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, 2.5-inch, 6Gb/s
100GB Hot Plug 2.5-inch SSD
1 x 100 GB SATA SSD, 2.5-inch, 3Gb/s
NOTE:
All hard drives within a RAID array should be of the same capacity and rotation speed.
Use the same rotational speed of the SAS Hard drives in one system.
SAS and SATA hard drives must be installed in separate drive groups.
Up to two kinds of drives can be mixed in one system.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in
order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.
Please download RAID controller driver from the web to install Windows Server 2003 R2 in the
configuration. http://www.nec.com/en/global/prod/express/download/index.html