USERS_GUIDE_1080XD_hw
1-88
1.7. TROUBLESHOOTING
This section covers measures against troubles in basic processing devices and peripheral
devices. If the troubles are not solved even countermeasures are conducted, contact and
inform to a maintenance engineer.
(1) If the LED for ON/OFF in the main chasis does not illuminte even the AC switch on
the switch box at the top in the front panel of the cabinet is turned on
- Check for the AC power to the main cabinet.
- Check if the switch on the distribution board is ON.
- Confirm that the AC breaker in the receptacle box of the main chasis is on.
- Confirm that the a power code is connected to the main chasis or the receptacle box
of main chasis.
(2) If nothing appears on the cosole
- Check if the console power is ON.
- Check for the connection between the basic processing device and iSP card is
correct.
• Is a correct cable used?
• Are connectors connected firmly?
• Is IP address setup correct?
- Check whether the screen is display-prohibited or not, by pressing the Shift key
- Check if the console brightness is set to the lowest.
- Check if the connection between the VGA card in the PCIF box and the console is
correct.
(3) If command input is not possible
- Confirm that keyboard and mouse are correctly connected.
- Check if the connection between the BIO card in the PCIF box and keyboard and
mouse is correct.
• Is correct cable used?
• Are connectors connected firmly?
(4) The OS does not boot up
- Check if there are errors in the SP console
- Confirm that the DVD-ROM (CD-ROM) is correctly installed when booting up OS
from the DVD-ROM in the PCIF box.
- Confirm that the HDD is correctly installed when booting up OS from the HDD in
DeviceBay in the PCIF box.