1-33
1.4.7.4.4 SP command list
The following list includes the SP commands in categories.
System Control
CMD Command name Function
NML
mode
iSP
state
DF
Shut down System power
(override)
The iSP turns off the DC power of the specified
partition without notifying the SW(OS) even if it is
running..
X m
DN Shut down System power
If the specified partition is in S0 state, the iSP only
generates the SCI(POWBTN). Otherwise, the iSP
turns off the DC power directly.
X m
DP System Dump
The iSP generates the INIT signal to the specified
partition. SW(OS) will enter its dump routine.
X m
PC Power Cycle
The iSP turns off the DC power of the specified
partition without notifying the SW(OS) even if it is
running, turns on the DC power, initializes HW
and hands off the control to the BIOS.
X m
RS Cold Reset System
The iSP initializes the specified partition without
notifying the SW(OS) even if it is running.
X m
UP Bring up System
The iSP turns on the DC power of the specified
partition and initializes HW and hands off the
control to the BIOS. The BIOS will boot the
Operating System.
X m
SR
Save system CMOS/
NvRAM
Save and/or restore the system
CMOS/NvRAM.
X m
NML mode: Availability or Unavailability of operation in the normal mode. X means
available.
m: Availability or Unavailability of operation in the master iSP.
(Reference) System state transition and System control commands
DC OFF
DC ON
Not running
Ready
SW running
UP/PC
DN/DF
UP/PC/RS
DN/DP
(only trigger)
DF
RS
PC