BMC Configuration User's Guide
40
4.2.14 Miscellaneous
This screen displays and sets the various functions of BMC.
Item Description Default Value
SEL SEL setting
Behavior when SEL
repository is full
Select the Behavior when SEL repository is full. *1
Stop logging SEL
: SEL is not recorded any more.
Clear all SEL
: Delete all SEL and record SEL newly.
Overwrite oldest SEL
: Old SEL is overwritten with new SEL.
Stop logging SEL
Power Restore Delay Power Restore Delay setting
AC-Link Select the AC-Link setting.
Stay Off
: DC is not turned on.
Last State
: It becomes the same as time when AC was turned off.
Power On
: DC on always.
Last State *2
Delay Time Set the value or specify the Random. The range is from
"Minimum value" to "600"[Sec], *3
Minimum value
PEF PEF setting
Platform Event Filter Select Enable/Disable of Platform Event Filter. *4 Enable
Management Software Management Software setting