3.3 Requirements for connection between PC for Management and
managed server
Provide an environment in accordance with the connection type to be used.
LAN connection
- TCP/IP network
Note
Do not use a cross cable to connect PC for Management and managed server.
If you use the managed server integrated BMC, LAN port that BMC uses depends on the type of
BMC. Some BMC uses standard LAN port. Other BMC uses a Management LAN Port. There are 2
types of managed servers on that BMC uses standard LAN port to connect with NEC ESMPRO
Manager: one type is permitted to use only LAN1 port, and the other type is permitted to use both
LAN1 and LAN2 ports. See "Appendix D Managed Servers Summary" in "NEC ESMPRO Manager
Ver.6 Setup Guide".
Modem connection (Only available for BMC connection)
- Phone line
- Modem
Use a modem that su
Baud rate : 19.2Kbps
Data bits : 8bit
pports the following functions:
Parity : None
it
Flo
Stop bits : 1b
w control : Hardware (CTS/RTS)
Note
Use the modem recommended for NEC Express 5800 series on the managed server.
Connect the modem to the serial port 2 on the managed server.
- Other Information
When BMC send alert to PC for Management via modem, it is necessary the following:
Dial-up router or PPP server
Direct connection (Only available for BMC connection)
- RS-232C cross cable
The serial port for direct connection on ESMPRO server. NEC ESMPRO Manager must be set following
on OS.
Bits per speed : Be set a same value with a value of BMC configuration on a managed server.
The default value of BMC configuration is 19.2Kbps.
Data bits : 8bit
Parity : None
Stop bits : 1bit
Flow control : Hardware (CTS/RTS)
Important
Do not use an interlink cable.
Connect RS-232C cross cable to serial port 2 on the managed server.
Some models of managed servers do not permit use of any RS-232C cross cable other than the
specified one. See Maintenance Guide provided with the server.