Monitoring Flash Backup Unit Status
The Universal RAID Utility can monitor Flash Backup Unit status which the RAID Controller detects by the following
means.
RAID Viewer
raidcmd
RAID Log Buzzer OS Log Alert
Depending on type of
RAID Controller
The Universal RAID Utility monitors events of the Flash Backup Unit installed in the RAID Controller. The Universal RAID
Utility logs detected Flash Backup Unit events in the RAID Log. Any event indicating occurrence of a problem in the Flash
Backup Unit reflects to the [Status] of Flash Backup Unit on RAID Viewer and the [Flash Backup Unit Status] of RAID
Controller on raidcmd (changes the status to [Warning]). The Flash Backup Unit status is retailed until the problem is
solved.
Tree View of RAID Viewe
122
Figure 29 Display of RAID Viewer / r
aidcmd (Abnormal Flash Backup Unit operation)
> raidcmd property -tg=rc -c=1
RAID Controller #1
ID : 0
Vendor : LSI Corporation
Model : LSI MegaRAID SAS
9270CV-8i
Firmware Version : 3.152.105-1754
Cache Size : 1,024MB
Premium Feature : CacheCade
Flash Backup Unit Status : Normal
Rebuild Priority : Middle
Consistency Check Priority : Middle
The status of the node of Flash Backup Unit becomes [Warning] when there
are problem in Flash Backup Unit.
Property of RAID Viewe
The [Status] of Flash Backup Unit Properties becomes [Warning] when there are problem in Flash Backup Unit.
Become [Warning] by existence
of [Warning] node.
bnormal Flash Backup Unit
[Warning]
bnormal Flash Backup Unit
[Warning]
Property of raidcmd
The [Flash Backup Unit Status] of RAID Controller Properties becomes [Warning] when there are problem in Flash Backup
Unit.
> raidcmd property -tg=rc -c=1
RAID Controller #1
ID : 0
LSI CorporatVendor : ion
Model : LSI MegaRAID SAS
9270CV-8i
Firmware Version : 3.152.105-1754
Cache Size : 1,024MB
Premium Feature : CacheCade
Flash Backup Unit Status : Warning
Rebuild Priority : Middle
Consistency Check Priority : Middle
bnormal Flash Backup Unit
[Warning]