8
Event ID
(hex digit)
Severity Description Log Alert Summary Deal Method
0604
(C000025C)
Fatal [Address Type 4 ] The temperature of Enclosure is Fatal
level.
RO MA Enclosure Temperature
Fatal
Please check the Fan Unit of the Enclosure. If some
kind of problem happens to the Fan Unit, please deal
with the problem.
0605
(8000025D)
Warning [Address Type 5 ] An error happened to the Power Supply
Unit of Enclosure.
RO MA Enclosure Power Supply
Unit Error
Please check the Power Supply Unit of the Enclosure. If
some kind of problem happens to the Power Supply
Unit, please deal with the problem.
0606
(8000025E)
Warning [
Address Type 6
] An error happened to the Fan Unit of
Enclosure.
RO MA Enclosure Fan Unit Error Please check the Fan Unit of the Enclosure. If some
kind of problem happens to the Fan Unit, please deal
with the problem.
0607
(4000025F)
Information [Address Type 4 ]
The temperature of Enclosure is Normal
level.
RO MA Enclosure Temperature
Normal
None
0701
(400002BD)
Information
[Address Type 1 ] The Configuration was cleared.
Configuration Cleared
None
0702
(400002BE)
Information raidsrv Configuration
[CTRL:%1(ID=%2)] Vendor Product Firmware Version
[LD:%3(ID=%4)] RAID:RAIDlevel PD:X,Y,Z (count of LD
STS:Status
[PD:%5(ID=%6 ENC=%7 SLT=%8] Vendor/Model Firmware
Version STS:Status
%1 : Number of RAID Controller
%2 : ID of RAID Controller
%3 : Number of Logical Drive
%4 : ID of Logical Drive
%5 : Number of Physical Device
%6 : ID of Physical Device
%7 : Enclosure Number of Physical Device
%8 : Slot Number of Physical Device
X, Y, Z : Number of Physical Device used in Logical Drive.
There is not the STS of PD when the device type is not HDD
or HDD(SSD).
O
0801
(C0000321)
Fatal
It became unable to manage the RAID System due to a fatal
error on the operating system.
RO MA Operating System Fatal
Error
Please solve the fatal error on operating system. This
event is reported by insufficient free memory space,
insufficient free disk space or any other causes. Please
refer Universal RAID Utility User's Guide for detail.
*1 : This item may not include in log message by the type of RAID Controller
Vista de pagina 7
1 2 3 4 5 6 7 8

Comentarios a estos manuales