45
2.2.24 getBmcInfo
Syntax:
dscli getBmcInfo Component [/x ModuleNo]
Description:
Obtains BMC configuration information of a specified managed component.
Options:
Component
Specify the name, the MAC address of LAN port that BMC uses, or the GUID of the managed
component.
/x ModuleNo
Specify the CPU/IO module number (0 or 1) if the managed component is a fault tolerant server. This
parameter is valid for the network items.
For the network items, this command obtains the setting of the CPU/IO module 0 if you omit this
parameter for the fault tolerant server.
For the other items, this command obtains the setting of the current primary CPU/IO module regardless
of the parameter.
Specify the Master BMC(0) or Standby BMC(1) if the managed component is the server which has
EXPRESSSCOPE Engine SP3 (2BMC model). This option is valid for network configurations.
For the network property items, this command obtains the setting of the Master BMC(0) if you omit
this parameter for the server which has EXPRESSSCOPE Engine SP3 (2BMC model).
Output:
Displays BMC configuration information. See 2.2.23 setBmcInfo for details.
The following shows an example.
CFG_COMPUTER_NAME=Component1
CFG_COMMUNITY=public
CFG_ALERT_ALL=1
CFG_POLICY=1
CFG_ALERT_ACKNOWLEDGE=1
CFG_ALERT_LEVEL=4
CFG_LAN_REDIRECTION=1
CFG_LAN_CONTROL_LAN1=1
CFG_SERIAL_REDIRECTION=1
CFG_SERIAL_CONTROL=1
CFG_LAN_IP_LAN1=192.168.14.14
CFG_LAN_SUBNET_LAN1=255.255.255.0
CFG_LAN_GATEWAY_LAN1=192.168.14.1
CFG_LAN_MANAGE1_ALERT_LAN1=0
CFG_LAN_MANAGE1_IP_LAN1=0.0.0.0
CFG_LAN_MANAGE2_ALERT_LAN1=0
CFG_LAN_MANAGE2_IP_LAN1=0.0.0.0
CFG_LAN_MANAGE3_ALERT_LAN1=0
CFG_LAN_MANAGE3_IP_LAN1=0.0.0.0
CFG_LAN_ALERT_RETRY_COUNT_LAN1=3
CFG_LAN_ALERT_RETRY_TIMEOUT_LAN1=6
:
:
Comentarios a estos manuales