ftGateway Alarm Messages
4-10 Express5800/320Ma: Technical Reference Guide
ftGateway Alarm Messages
Table 4-9 presents the ftGateway alarm messages.
Miscellaneous Alarms
Table 4-1 0 presents miscellaneous alarm messages, some of which are not specifically
related to particular devices.
Table 4-9. ftGateway Alarm Messages
Alarm Message
Alarm
ID
Send to NEC
Technical
Support
Send to
Pager
Email
Generate
SNMP
Trap
New ftGateway group created. 30019 Yes – No
ftGateway group removed. 30020 Yes – No
New slave added or removed from
the ftGateway group.
30021 Yes – No
ftGateway warning: slave %1 not
responding.
30022 Yes – No
Table 4-10. Miscellaneous Alarm Messages and Message Destinations
Alarm Message
Alarm
ID
Send to
NEC
Technical
Support
Send
to
Pager
Email
Generate
SNMP
Trap Notes
Device %1 inserted into
system.
30007 No – No Include device
inventory only.
CPU Board '%1' went empty
unexpectedly. This may have
been caused by an unexpected
loss of power.
30009 Yes – No Include device
inventory only.
I/O Adapter '%1' went empty
unexpectedly. This may have
been caused by an unexpected
loss of power.
30010 Yes – No Include device
inventory only.
Unknown alarm ID %2 from
device '%1'.
30014 Yes P,E No Include device
inventory only.