ND-70684 (E) CHAPTER 3
Page 29
Revision 1.0
DATA PROGRAMMING
Data Programming Procedure for Add-On Module
4. Data Programming Procedure for Add-On Module
When assigning Add-On Module data, perform the following procedure. “X” indicates the value should be tai-
lored to the existing system.
STEP 1: ASDT
Assign a D
term
to an even-numbered LEN level. (In this example, LV 0 is used.) Assign the Add-On
Module to the subsequent odd-numbered LEN level. (In this example LV 1 is used.)
STEP 2: AKYD
Assign Line/Feature access keys to the Add-On Module. The upper 24 Line/Feature access keys be-
long to the associated D
term
and the remaining lower 36 Line/Feature access keys belong to the Add-
On Module.
Use the associated D
term
port to assign information for the D
term
and first 24 keys on the ADM.
TN : X
STN : 201
LEN : 0 0 0 1 0 1 Odd-numbered LEN level
TEC : 1 2 Fixed
RSC : X
SFC : X
TN : X
STN : 200
TP : 1 Buttons 1-39 are assignable
PRI : 0
PL TN : X
PL STN : 200
S : 0 = Off Hook Suppression is off
MWD : X
LN PRE : 0 = Prime Line Pickup
KYN : 1-16 For D
term
17-40 Correspond to KYNs (1-24) on the Add-On Module
KY1 : X
KD : X
TN : X
STN : XXXX
RG : X
ICM : X
G-ID : X