====================================================================== Control Commands for NEC Projector (Basic) Rev 5.16.11a Copyright (C) NEC Di
00H : Start is not requested 01H : Cannot process due to storing 02H : Exceeds the total number of blocks required
==================================================================== 4. List of Commands -----------------------------------------------------------
07 : GT5000 08 : LT240K/LT260K 09 : GT6000 10 : HT1100 11 : VT770 12: HT410/HT510 (HT10 Series) 13 : LT245/LT265 14 : LT280/LT380 15 : LT180
Meaning of Symbols--------------------------------------------------------------------* Supported! Is available depending on model's version-
Command Name 1 2 3 4 5 6 7 8 9 10111213141516171819202122232428006. RUNNING SENSE ***********-**-- -**- --***007
In case of V300 series 20H In case of VT series 40H In case of NP600 series 40H In case of NP610 series 40H I
Bit 7: Power On/Off processing 0 = No execution (Normal condition) 1 = During execution
01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During
DATA32 Freeze Status (!2) 00H : OFF 01H : ON FFH : Not Supported DATA33 Test pattern display 1
00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation
====================================================================== Contents 1. Projector Control 2. Connection Method 3. Interface Condit
Data01 Data70 Data7101H 00H 03H MT1060/MT106501H 01H 03H MT86001H 02H 03H MT107501H 00H 06H NP1000/NP200002H 00H 03H LT240/LT26002H 01H 03H LT22002H 0
DATA72 PC Card insertion 00H : Not inserted 01H :
009. ERROR STATUS REQUEST ********************************************************************** Function: This command acquires the error informatio
Supplement: (!) LT/LT80/HT: "None" 015. POWER ON ********************************************************************** Function: This
DATA02 Switching number --------------------------------------------------------- When the switching object is the &qu
Response: At the time of a success 22H 03H 01H xxH 01H DATA01 CKS (*1) (*2) (*3) Data Por
022. SOUND MUTE ON ********************************************************************** Function: This command mutes the sound. Command: 02H
025. ONSCREEN MUTE OFF ********************************************************************** Function: This command cancels the blanking of the on
DATA03 : 00H (direct settings) 01H (increment/decrement) DATA04 : lower data (8bit) DATA05 : upper data
------------------------------------------------------------------- DATA01 .. 02 Results 0000H : Normal 0000H
(!2) Only the M300 series is compatible. [P350X/P350W/P420X Series]STANDBY MODE: "POWER-SAVING"Control CommandSerial portWired LAN portWirel
DATA04 DATA05Aspect Ratio 4:3 (Window) 00H 00HAspect Ratio Normal / Auto (NP600, NP610, NP2200, NP62, NP64, NP216, P420, PA600, U300, V300 Series) 00
Supplement: (!) Lamp Hour Meter This is the timer for normal lamp mode conversion. Lamp Timer Acquisition Examples DATA83 DATA84 DATA85 DA
2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00) 3) Change from HEX to Decimal - value will change to 7200000 seconds Lamp remaining ti
to appear (in terms of Eco mode values) 10H : Remaining time until inhibition of lamp usage
Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS
Lamp Use Warning Starting Time 2000[H] Model. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp Hour Meter This is the timer f
00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 C
01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2
Key number DATA01 DATA02 Key name --------------------------------------------
81 51H 00H S-VIDEO1 (!!) 82 52H 00H S-VIDEO2
(1) (2) (3-1) (3-2) (3-3) (3-4)GT5000/GT6000 Yes Yes Yes Yes Yes NoGT1150/GT2150 Yes No Yes Yes Yes NoHT410/HT510 Yes No No No No NoHT1000/HT1100 Yes
Command example: * Sending the AUTO key code 02H 0FH 00H 00H 02H 05H 00H 18H * Sending the AUTO (SHORT) key code 02H 0FH 00H 00H 0
Function: This command acquires the Carbon Saving values on the projector. Command: 03H 9AH 00H 00H 01H DATA01 CKS
Function: This command acquires the adjustment values. Command: 03H 04H 00H 00H 03H DATA01 .. DATA03 CKS
(! ) Acquirement itemsDATA01 DATA02 Acquirement name00H 00H Picture / Brightness01H 00H Picture / Contras
4CH 07H Color Correction / Yellow4CH 08H Color Correction / Magenta4CH 09H Color Correction / Cyan4CH 0AH Color Correction / White4DH 00H Through4EH 0
077. MUTE CONTROL ********************************************************************** Function: This command controls the mute of picture, sound a
DATA01 DATA02 DATA0301H 00H 03H MT1060/MT106501H 01H 03H MT86001H 02H 03H MT107501H 00H 06H NP1000/NP200002H 00H 03H LT240/LT26002H 01H 03H LT22002H 0
DATA04 Sound function 00H : Not available 01H : Available DATA05 Calendar function
01H : Connected DATA09 .. 16 Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 DATA02 CKS
DATA06 Test pattern display 00H : No display(Normal condition) 01H : Displaying DATA07 ..08 Reserved
Before making connections, set the standby mode of the projector to "NORMAL" or "Idol mode". The projector cannot use the c
078-5. MODEL NAME REQUEST ********************************************************************** Function: This command acquires the model name of
[079. FREEZE CONTROL] ********************************************************************** Function: This command controls the freeze. Command:
Command: 03H B0H 00H 00H 02H DATA01 DATA02 CKS Data Portion Contents ---------------------------------------------------------------
02H : BOTTOM-LEFT 03H : BOTTOM-RIGHT if DATA02 is SOURCE(02H) 00
111. AUTO ADJUST EXECUTE2 ********************************************************************** Function: This command executes the Auto Adjust.
DATA02 DATA03 DATA13 DATA1400H 01H 00H 03H MT1060/106500H 01H 02H 03H MT86000H 01H 02H 03H MT107500H 01H 00H 06H NP1000/NP200000H 02H 00H 03H LT240/LT
DATA15 ... 16 Reserved Response: At the time of a failure A0H BFH 01H xxH 02H DATA01 DATA02 CKS
09H : SLOT2 0AH : SLOT3 0BH : SLOT4 0CH : DIGITAL2
====================================================================== 6.1. Response ----------------------------------------------------------------
The PC CONTROL connector is a D-SUB 9-pin connector. 1 2 To TxD of PC 3 To RxD of PC 4 5 To GND of PC 6 7 To CTS of
Command : This sets an identification data assigned to each command to send it. ( See each command description.) Response : This returns the 6th
basis Broadcast notification is recommended. * When the controller is connected with multiple projectors To control a certain projector, use &q
4-2. Data portion of response ********************************************************************** For ACK This returns ACK without adding data
Comentarios a estos manuales