855-900549-A Rev. 1 NX7700i/5020M-16 Operation Manual CAUTION Before using the product, be sure to read this manual and strictly adhere
ix Preface This document explains how to operate the hardware of the base module, the main body of this system. It is recommended that the related d
Base Module 855-900549 2-81 b) partition boot methods and Hot-plug permission a) display all settings Select ? (c/p/b/a/CR=back) : <ENTER>
Base Module 855-900549 2-82 LAN1 IP address : 192.168.100.231 (ISPF only) LAN1 subnet mask : 255.255.255.128 (ISPF only) g
Base Module 855-900549 2-83Display and modify settings of system and iSP. s) system settings i) iSP settings a) display all settings Select ?
Base Module 855-900549 2-84default FTP account (CR=skip) : <ENTER> default FTP password (CR=skip) : <ENTER> Re-enter default FTP password
Base Module 855-900549 2-85 i) iSP settings a) display all settings Select ? (s/i/a/CR=exit) : i<ENTER> iSP setting menu: c) LAN/Serial
Base Module 855-900549 2-86 Manager IP 2 : N/A (Other than ISPF) community(Trap) : public community(Get) : public
Base Module 855-900549 2-872.4.6.13. SR (Save System CMOS/NvRAM) m b u X * For cautions for using this command, read the following description o
Base Module 855-900549 2-88ERROR: cmossave/cmos2.bin does not exist. Enter partition number? (0-7/CR=exit) : (k) checking downloaded file. passed. res
Base Module 855-900549 2-892.4.6.14. UB (Bring up BIOS) m b u X * The command is executable to the active partition (after automatic system boot
Base Module 855-900549 2-902.4.6.15. UP (Bring up System) m b u X * This command is valid to inactive partitions (DC Off). Function: This comman
xContents Chapter 1 NX7700i/5020M-16 System Overview ...1-1 1.1. Configuration and S
Operation Procedure 855-900549 3-1Chapter 3 Operation Procedure 3.1. System Startup 3.1.1. System Startup Procedure When all installation is comp
Operation Procedure 855-900549 3-2 StartTurn on distribution board. (See step 1 in next page.) Turn on conso
Operation Procedure 855-900549 3-3 Startup Flowchart Step Operation 1 Turn on the power distribution board. 2 Turn on the console PC. 3 Turn on
Operation Procedure 855-900549 3-4of the association between these switches and base modules and expansion power bays during switch operation. The sw
Operation Procedure 855-900549 3-53.1.2. SP Console Messages SP console messages displayed during system startup are explained below. 1) Example o
Operation Procedure 855-900549 3-62) Example of SP console screen during system startup Note: When multiple partitions
Operation Procedure 855-900549 3-73.2. System Shutdown 3.2.1. System Shutdown Procedure The procedure to turn off the AC power with the AC switch i
Operation Procedure 855-900549 3-8 StartShut down OS. (See step 1 in next page.) Turn off console PC. (See
Operation Procedure 855-900549 3-9Shutdown Flowchart Step Operation 1 Enter “shutdown –h now” on the OS console. 2 Check that “Power down.” is di
Operation Procedure 855-900549 3-103.2.2. SP Console Messages The SP console messages displayed during system shutdown are explained in this sectio
xi2.4.6.4. DT (SP Data and Time) ...2-37 2.4.6.5. EN (Environmental Info
Operation Procedure 855-900549 3-113.3. Emergency System Shutdown with AC SW The switches on the switch panel are provided for forced power off in t
Operation Procedure 855-900549 3-121) SP console screen and operation during AC LINK setup iSPyz:---> sg<EN
Operation Procedure 855-900549 3-133.5. OS Boot CAUTION Use the OS console to operate the EFI Shell. Inputs from the VGA console (PS2 keyboard) may
Operation Procedure 855-900549 3-143.5.2. OS Boot from the EFI (Extensible Firmware Interface) Boot Manager OS boot options are automatically entere
Operation Procedure 855-900549 3-153.5.3. EFI Shell The EFI Shell can be activated from the EFI Boot Manager. The EFI Shell provides Shell commands f
Operation Procedure 855-900549 3-16Command Description cd cd [path] Display/change the current directory. child child Handle Display the device
Operation Procedure 855-900549 3-17Command Description ls ls [-b] [-r] [-a [attrib]] [file] Display directories/file lists. map map [-r|-v|-d] [s
Operation Procedure 855-900549 3-183.5.5. OS Boot from EFI Shell In addition to OS boot from the EFI Boot Manager, the OS can be booted by entering
Operation Procedure 855-900549 3-19(2) Booting the OS loader Boot OS loader SuSE Linux (elilo). Image of OS loader boot screen fs0:¥> cd os
Operation Procedure 855-900549 3-203.5.6. EFI Devices The device connected to the system is managed as “EFI device path.” This section explains the E
NX7700i/5020M-16 System Overview 855-900549 1-1Chapter 1 NX7700i/5020M-16 System Overview This system is a server that implements the following by
Operation Procedure 855-900549 3-21 Computing UID: UID x=LIOC*16 LIOX=Logical IOX Number :Logical IOX number: LIOX=0-7 LIOC=Logical IOC Number
Operation Procedure 855-900549 3-22Example: To install the boot device on the PCI bay (PCI module): Host Bus PEX PXH Slot -------------------------
Operation Procedure 855-900549 3-233.5.7. EFI Boot Option Maintenance A boot option can be selected on the Boot Option Maintenance Menu which is act
Operation Procedure 855-900549 3-24Boot Maintenance Menu Options Option Description Boot from a File Boot the OS directly from the EFI application.
Operation Procedure 855-900549 3-253.5.7.1. Boot from a File A boot file can be selected from a list of device files by selecting [Boot from a File]
Operation Procedure 855-900549 3-263.5.7.2. Add a Boot Option To add a new boot option to the EFI Shell, select [Add a Boot Option] on the Main Menu
Operation Procedure 855-900549 3-273.5.7.3. Add Boot Option(s) To delete a boot option or all options, select [Delete Boot Option(s)] from the Main
Operation Procedure 855-900549 3-283.5.7.5. Manage BootNext Setting To set the most favored boot option for the next boot or reset the BootNext opt
Operation Procedure 855-900549 3-293.5.7.6. Set Auto Boot Timeout To change the timeout value until the next auto boot (TimeValue) from the default
Operation Procedure 855-900549 3-303.5.7.7. Setting the Network Boot To enable PXE Boot, change the EFI Boot Manager using the EFI Boot Option Mainte
NX7700i/5020M-16 System Overview 855-900549 1-21.1. Configuration and Specifications of the Base Module The base module of this system is composed of
Operation Procedure 855-900549 3-31Changing procedure: 1) Activate the EFI Boot Manager. 2) Select Boot Option Maintenance Menu. 3) Select Add Boo
Operation Procedure 855-900549 3-323.5.7.8. Changing BIOS Settings The BIOS settings may need to be changed using the EFI System Configuration Menu.
Operation Procedure 855-900549 3-33OS Setting (Note) -------------------------------------------------------- ------------------- Windows Server 20
Operation Procedure 855-900549 3-343.6. System Dump The system dump can be produced by following the procedure explained below if the OS is corrupt (
Troubleshooting 855-900549 4-1Chapter 4 Troubleshooting This chapter shows general actions to errors in the base module and peripheral units. If a
Troubleshooting 855-900549 4-2pressing the SHIFT key on the screen. • Check that the VGA console brightness is set to the proper level. (4) Console
Notes on Handling 855-900549 5-1Chapter 5 Notes on Handling 5.1. Transportation When the product is transported, pack it with the packing materials
Notes on Handling 855-900549 5-25.4. Cleaning • Wipe the surface of the main and peripheral units with soft cloth. • Take out the power plug of the
Notes on Handling 855-900549 5-35.5. Notes on Installation • Do not put things on the cabinet. It does not have safety measures to prevent things p
Notes on Handling 855-900549 5-4 ----- Memo -----
NX7700i/5020M-16 System Overview 855-900549 1-3 Front View Rear View Figure. Layout of Parts in the Ba
NX7700i/5020M-16 System Overview 855-900549 1-4Table. Base Module Specifications BASE MODULE Cell (Max. 2 cells can be installed in the base module.)
NX7700i/5020M-16 System Overview 855-900549 1-5Table. Base Module Specifications (Cont’d) Main Cabinet Cabinet size/weight Note 2) Width 600mm
NX7700i/5020M-16 System Overview 855-900549 1-61.2. Expandability This section explains the expandability of this system and available configurations.
NX7700i/5020M-16 System Overview 855-900549 1-7 Figure. System Configuration 10/100Base - TX RS232C(Console)Se
Disposing of your used NECIn the European UnionEU - wide legislation as implemented in each Member Statethat used
Base Module 855-900549 2-1Chapter 2 Base Module This chapter covers operations required on the base module of this system. Locking/un
Base Module 855-900549 2-22.1. Partition Function The base module has the partition function which enables the system to operate as if multiple units
Base Module 855-900549 2-32.2. Name and Function of Components 2.2.1. Cabinet (Primary Cabinet) The base module and expansion power bay (POWBAY#1)
Base Module 855-900549 2-42.2.2 Base Module A base module is composed of cells, iSP cards, I/O modules, power bays, and DPSs. 2.2.3 Expansion Power
Base Module 855-900549 2-52.2.6. Power Bay The power bay supplies power to the system. A maximum of three DPSs (a DPS is a system power supply with a
Base Module 855-900549 2-62.2.7. iSP One iSP-C card is mounted on the base module as standard equipment. It contains the following interfaces: 1) 10/
Base Module 855-900549 2-72.2.8. DVD-ROM Unit One DVD-ROM unit can be installed for each I/O module. A DVD-ROM unit is mounted on each I/O module as
Base Module 855-900549 2-82.2.9. DAT Unit An optional DAT unit can be installed in the I/O module. 2.2.9.1. Location of Index Labels The figure belo
Base Module 855-900549 2-92.2.9.4. Cleaning the DAT Unit Wipe off the dusts on the DAT unit. See 2.2.9.5 to 2.2.9.7 for how to clean the DAT unit.
Base Module 855-900549 2-102.2.9.9. Notes on the DAT Unit Avoid placing the DAT unit in the following locations as much as possible to prevent troubl
iiSafety Precautions Before using the product, read this manual carefully to ensure the proper and safe operation of the product. Follow the instr
Base Module 855-900549 2-112.2.10. Notes on Installing the UPS To installed the UPS, remove the signal cable for power control (on/off), and mount a
Base Module 855-900549 2-12b) Power supply from two systems Location on the inlet box: P1 Location on the expansion power bay: P3 c) P
Base Module 855-900549 2-132.2.11. System LEDs System LEDs are located at the upper left of the front panel of the base module and indicate the syste
Base Module 855-900549 2-142.3. Consoles The base module contains console interfaces as standard equipment. The consoles connected to the interfaces p
Base Module 855-900549 2-15 Figure. Console Connection Diagram BASE MODULE SYS BP CELL CARD I/O MODULE LAN C
Base Module 855-900549 2-162.4. Service Processor (SP) This system contains interfaces to offer advanced system management and RAS function to the us
Base Module 855-900549 2-172.4.1.3. Console Status and Login Authentication To gain access to console operation, you must first login to the iSP. W
Base Module 855-900549 2-18 iSP login prompt Main Menu Serial console inoperative TCP-5001 not connected Press ESC Connect TCP5001 Login password re
Base Module 855-900549 2-192.4.1.4. Login and Main Menu Immediately after a console is attached to the iSP, login prompts appear on the console, wai
Base Module 855-900549 2-20 (Description) Description No. Description (a) xx is a cabinet ID identifying a particular cabinet in a multi-cabinet syst
iii WARNING Do not touch the internal components of the equipment Nobody except the maintenance personnel should open the door of the equipment. Do
Base Module 855-900549 2-21 • Possible Events (including operator entries) and System Responses Event System Response Login account or password was
Base Module 855-900549 2-222.4.3. OS (BIOS) Console If OS (BIOS) Console is chosen from the iSP Main Menu, I/O to/from the serial controller is redir
Base Module 855-900549 2-23(Description) Description No. Description (a) If a value (0 to 7) is entered, I/O is redirected to OS Console within the c
Base Module 855-900549 2-242.4.4. Virtual SOP If Virtual SOP (Virtual System Operator Panel) is chosen from the Main Menu, Virtual SOP appears on the
Base Module 855-900549 2-25 (Description) Description No. Description (a) Virtual SOP appears if V is entered at this prompt. (b) Virtual SOP scree
Base Module 855-900549 2-262.4.4.1. Details of Partition Status Display The status information for each partition consists of the following items:
Base Module 855-900549 2-272.4.5. SP Command Console If SP Command is chosen from the iSP Main Menu, SP Command Console appears on the console scree
Base Module 855-900549 2-282.4.5.1. SP Command Console Buffer The output from SP Command Console may contain some critical information such as causes
Base Module 855-900549 2-292.4.5.4. SP Command List The following tables contain SP command lists by category: System Control CMD command name fun
Base Module 855-900549 2-30(Reference) System Status Transitions and System Control Commands DC OFFDC ONNot runningReadySW runningUP/PCDN/DFUP/PC/RS
ivHandling of the laser product A laser product of Class 1, Subchapter J, Chapter 1 of JIS C6802, EN60825, IEC825 and FDA21CFR, is used for this equ
Base Module 855-900549 2-31 Configuration CMD command name function iSP state HC Hardware Configuration Display and/or modify the hardware configura
Base Module 855-900549 2-322.4.6. SP Command Reference This section provides command reference describing the details of SP commands. Command availab
Base Module 855-900549 2-332.4.6.1. DF (Shut down System Power <override>) m b u X * The command is executable to the active partition (af
Base Module 855-900549 2-34(Description) Description No. Description (a) Enter the target partition number at this prompt. If “all” is specified, all
Base Module 855-900549 2-352.4.6.2. DN (Shut down System Power) m b u X * The command is executable to the active partition (after automatic sy
Base Module 855-900549 2-362.4.6.3. DP (System Dump) m b u X * The command is executable to the active partition (after automatic system boot/UP
Base Module 855-900549 2-372.4.6.4. DT (SP Data and Time) m b u X X X * Always valid without regard to the current system status. Function: This c
Base Module 855-900549 2-382.4.6.5. EN (Environmental Information) m b u X * Always valid without regard to the current system status. Functio
Base Module 855-900549 2-39(32Way) ---- MAIN cabinet FANs ----------------------------- 19:20:57,01/31/2005 ---- Location FR00 FR01 FR02
Base Module 855-900549 2-40Previous/Next page? (p[revious]/n[ext]/e[xit]/CR=next) : <ENTER> (The total number of pages and page numbers depend
v140 注※意:同型同定格のヒューズと交換すること。 CAUTION:For continued protection against risk of fire, replace only with same type and ratings of fuse. ATTENTION:Pou
Base Module 855-900549 2-41---- Temperature (Celsius) [4/7] ------------------- 19:20:57,01/31/2005 ---- current threshold
Base Module 855-900549 2-42(The numbers of PCI Bay cards are changed on 32Way/8Way and ISPF.) ---- Temperature (Celsius) [7/7] ------------------- 19:
Base Module 855-900549 2-43(Description) Description No. Description (a) Allows to choose environmental data formats from page format of 24 lines eac
Base Module 855-900549 2-442.4.6.6. FV (Firmware Versions) m b u X X X * Always valid without regard to the current system status. Function: This c
Base Module 855-900549 2-452.4.6.7. HC (Hardware Configuration) m b u X * For system states and subcommand validity, read the description of subc
Base Module 855-900549 2-46cmd arg1 arg2 arg3 arg4 Description mmxxy - - - Show the detailed configuration of the ROW under the MMX specified by xy,
Base Module 855-900549 2-47cmd arg1 arg2 arg3 arg4 Description cellx n m - Attach the CELL Card having physical CELL number x to partition number n
Base Module 855-900549 2-48cmd arg1 arg2 arg3 arg4 Description - - - - This command is currently not supported.This command can be used to swap a CEL
Base Module 855-900549 2-49cmd arg1 arg2 arg3 arg4 Description - - - - Use this command to manually inform the iSP of an addition of components.
Base Module 855-900549 2-50cmd arg1 arg2 arg3 arg4 Description memdx - - - This command is only valid to the 32Way model. Use it to add MMX (2-3
vi243 注※意:カバーを開ける前に入力電源(分電盤)切断のこと。 CAUTION:Disconnect input power before removing this cover. ATTENTION:Couper l'alimentation electrique ava
Base Module 855-900549 2-51cmd arg1 arg2 arg3 arg4 Description pbayx - - - Enable the Power Bay. x is a Power Bay number. The allowable value of
Base Module 855-900549 2-52cmd arg1 arg2 arg3 arg4 Description rowxzz - - - Enable the ROW. x is a physical CELL number (0-7). zz is a ROW number (0
Base Module 855-900549 2-53cmd arg1 arg2 arg3 arg4 Description - - - - Use this command to manually “DISABLE” the components that are currently
Base Module 855-900549 2-54cmd arg1 arg2 arg3 arg4 Description pcibx - - - Connect PCI Bays to the partitions to which they belong. x: Physical
Base Module 855-900549 2-55cmd arg1 arg2 arg3 arg4 Description clkx on|off - - Turn On/Off the LED on the CLK Card. x is a CLK Card number (0-1)
Base Module 855-900549 2-56cmd arg1 arg2 arg3 arg4 Description check - - - - This command is used to check the current system configuration focu
Base Module 855-900549 2-57Description of Status Indicator Strings Indicator string Description nonexist. Indicates that a resource is defined to be
Base Module 855-900549 2-58(Screen Example … Help Screen) Description No. iSPyz:---> hc<ENTER> iSP FW version is Rxx.xx. HC> help<E
Base Module 855-900549 2-59 part7(----) CELL:-------- (--------) IOX:-------- (--------) CIMB:----- ==============================================
Base Module 855-900549 2-60(8Way) ==== Summary (loc=M-00/08) =========================== 19:20:23,07/31/2005 === POWBAY0 (loc=M-00/08) power-ON
vii 133-314121-GRP MARKINGS 051 複数の装置を 同時に引き出さないで下さい。 ラックの破損、転倒などの事故の原因となります。 Do not pull out more than one component at a time as it may cause d
Base Module 855-900549 2-61(For 32Way(B)) ---- CELL0 ------------------------------------------- 19:20:23,07/31/2005 --- CELL0 (loc=M-14/23)
Base Module 855-900549 2-62(For ISPF) ---- CELL0 ------------------------------------------- 19:20:23,07/31/2005 --- CELL0 (loc=M-00/10) ONLI
Base Module 855-900549 2-63(For 32Way(H)) ---- MMX00 ------------------------------------------- 19:20:23,07/31/2005 --- MMX00
Base Module 855-900549 2-64(For 32Way(B), 8Way, or ISPF) ---- TAG0_e ------------------------------------------ 19:20:23,07/31/2005 --- TAG0_e0
Base Module 855-900549 2-65(For 32Way(B)) ---- XBX_C0 ------------------------------------------ 19:20:23,07/31/2005 --- XBX_C0(loc=M-14/23)
Base Module 855-900549 2-66(For 32Way, subsequently listed to the max. XBX Card number.) ---- XBX_C1 ------------------------------------------ 19:20:
Base Module 855-900549 2-67(8Way’s internal PCIBAY) ---- PCIBAY0(D) -------------------------------------- 19:20:23,07/31/2005 --- PCIBAY0(D) (loc=
Base Module 855-900549 2-68---- PCIBAY0(D) -------------------------------------- 19:20:23,07/31/2005 --- PCI001: VID:xxxx DID:xxxx PCI err_rec.:
Base Module 855-900549 2-69 DPS21 DPS22 INVISIBLE DPS23 DPS24
Base Module 855-900549 2-70(Description) Description No. Description (a) Lists partition configuration information. (b) Lists the configuration of th
viii 243-304367-GRP MARKINGS 001 243-306629-GRP MARKINGS 001 002
Base Module 855-900549 2-712.4.6.8. HE (Help) m b u X X X * Always valid without regard to the current system status. Function: This command is use
Base Module 855-900549 2-722.4.6.9. ML (Message Log) m b u X X X * Always valid without regard to the current system status. Function: This command
Base Module 855-900549 2-73(Description) Description No. Description (a) Allows to choose from two modes: one that prompts operator entry for each lo
Base Module 855-900549 2-742.4.6.10. PC (Power Cycle) m b u X * The command is executable to the active partition (after automatic system boot/UP
Base Module 855-900549 2-752.4.6.11. RS (Cold Reset System) m b u X * The command is executable to the active partition (after automatic system
Base Module 855-900549 2-762.4.6.12. SG (SP/System Setting) m B u X X X * Always valid without regard to the current system status. Function: This
Base Module 855-900549 2-77Category Configuration Parameter Default Setting Hot Plug permission [Hot Plug permission] Specifies whether Hot-Plu
Base Module 855-900549 2-78SP default FTP Server Configuration: Category Configuration Parameter Default SettingIP address for the default FTP serve
Base Module 855-900549 2-79 Screen examples for partition boot method and hot-plug permission Description No. iSPyz:MNT> sg<ENTER> Display
Base Module 855-900549 2-80Partition boot methods and Hot-plug permissions: ¦ ¦Wake ¦Hot-Plug permission part.¦ AC- ¦ On ¦ PCI-card
Comentarios a estos manuales